Filtered by vendor Schneider-electric
Subscriptions
Total
765 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-27976 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2025-02-05 | 8.8 High |
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above) | ||||
CVE-2023-29412 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2025-02-05 | 9.8 Critical |
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface. | ||||
CVE-2023-29413 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2025-02-05 | 7.5 High |
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service. | ||||
CVE-2023-29410 | 1 Schneider-electric | 6 Conext Gateway, Conext Gateway Firmware, Insightfacility and 3 more | 2025-02-05 | 7.2 High |
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute. | ||||
CVE-2022-43377 | 1 Schneider-electric | 10 Netbotz 355, Netbotz 355 Firmware, Netbotz 450 and 7 more | 2025-02-05 | 7.5 High |
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause account takeover when a brute force attack is performed on the account. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior) | ||||
CVE-2022-32513 | 1 Schneider-electric | 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more | 2025-02-05 | 9.8 Critical |
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0) | ||||
CVE-2022-32514 | 1 Schneider-electric | 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more | 2025-02-05 | 9.8 Critical |
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0) | ||||
CVE-2022-32522 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32523 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32524 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32525 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32526 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32527 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32529 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-24324 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
CVE-2022-2329 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
CVE-2022-42970 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2025-02-05 | 9.8 Critical |
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
CVE-2022-42971 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2025-02-05 | 9.8 Critical |
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
CVE-2022-0223 | 1 Schneider-electric | 1 Ecostruxure Power Commission | 2025-02-05 | 6.5 Medium |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22) | ||||
CVE-2022-22731 | 1 Schneider-electric | 1 Ecostruxure Power Commission | 2025-02-05 | 6.5 Medium |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22) |