CVE Vendors Products Updated CVSS v3.1
CVE-2024-2546 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-11 8.8 High
A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-57582 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-06 9.8 Critical
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the startIP parameter in the formSetPPTPServer function.
CVE-2024-57581 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-06 9.8 Critical
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
CVE-2024-57580 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-06 9.8 Critical
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
CVE-2024-57579 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-06 9.8 Critical
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp parameter in the formSetClientState function.
CVE-2024-2485 1 Tenda 2 Ac18, Ac18 Firmware 2025-02-13 8.8 High
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-34974 1 Tenda 1 Ac18 2025-02-13 8.2 High
Tenda AC18 v15.03.05.19 is vulnerable to Buffer Overflow in the formSetPPTPServer function via the endIp parameter.
CVE-2024-57583 1 Tenda 2 Ac18, Ac18 Firmware 2025-02-04 9.8 Critical
Tenda AC18 V15.03.05.19 was discovered to contain a command injection vulnerability via the usbName parameter in the formSetSambaConf function.
CVE-2024-57575 1 Tenda 2 Ac18, Ac18 Firmware 2025-02-03 9.8 Critical
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2023-30135 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-29 9.8 Critical
Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName parameter in the setUsbUnload function.
CVE-2024-2547 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2558 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2559 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-27 4.3 Medium
A vulnerability classified as problematic has been found in Tenda AC18 15.03.05.05. Affected is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257058 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2560 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-22 4.3 Medium
A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2489 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 8.8 High
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2490 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 8.8 High
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2488 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 8.8 High
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2487 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 8.8 High
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2486 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 8.8 High
A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.
CVE-2024-33180 2 Tenda, Tendacn 3 Ac18, Ac18, Ac18 Firmware 2024-11-21 9.8 Critical
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo.