Tungsten Automation Power PDF JP2 File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the parsing of JP2 files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-25566.
Metrics
Affected Vendors & Products
References
Link | Providers |
---|---|
https://www.zerodayinitiative.com/advisories/ZDI-24-1678/ |
![]() ![]() |
History
Thu, 20 Feb 2025 16:30:00 +0000
Type | Values Removed | Values Added |
---|---|---|
First Time appeared |
Tungstenautomation
Tungstenautomation power Pdf |
|
CPEs | cpe:2.3:a:tungstenautomation:power_pdf:*:*:*:*:*:*:*:* | |
Vendors & Products |
Tungstenautomation
Tungstenautomation power Pdf |
|
Metrics |
cvssV3_1
|
Wed, 12 Feb 2025 16:15:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Metrics |
ssvc
|
Tue, 11 Feb 2025 19:30:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Description | Tungsten Automation Power PDF JP2 File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JP2 files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-25566. | |
Title | Tungsten Automation Power PDF JP2 File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability | |
Weaknesses | CWE-125 | |
References |
| |
Metrics |
cvssV3_0
|

Status: PUBLISHED
Assigner: zdi
Published: 2025-02-11T19:24:26.785Z
Updated: 2025-02-12T15:37:07.137Z
Reserved: 2024-12-11T21:52:25.602Z
Link: CVE-2024-12550

Updated: 2025-02-12T15:37:02.883Z

Status : Analyzed
Published: 2025-02-11T20:15:33.800
Modified: 2025-02-20T16:05:43.313
Link: CVE-2024-12550

No data.