Filtered by vendor Mitsubishielectric Subscriptions
Total 161 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-0457 1 Mitsubishielectric 76 Fx5-enet, Fx5-enet\/ip, Fx5-enet\/ip Firmware and 73 more 2025-03-05 7.5 High
Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and login into FTP server or Web server.
CVE-2023-1424 1 Mitsubishielectric 78 Melsec Iq-fx5u-32mr\/ds, Melsec Iq-fx5u-32mr\/ds Firmware, Melsec Iq-fx5u-32mr\/dss and 75 more 2025-03-05 10 Critical
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules and MELSEC iQ-R Series CPU modules allows a remote unauthenticated attacker to cause a denial of service (DoS) condition or execute malicious code on a target product by sending specially crafted packets. A system reset of the product is required for recovery from a denial of service (DoS) condition and malicious code execution.
CVE-2023-2060 1 Mitsubishielectric 8 Fx5-enet\/ip, Fx5-enet\/ip Firmware, Rj71eip91 and 5 more 2025-03-05 7.5 High
Weak Password Requirements vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to access to the module via FTP by dictionary attack or password sniffing.
CVE-2023-2061 1 Mitsubishielectric 8 Fx5-enet\/ip, Fx5-enet\/ip Firmware, Rj71eip91 and 5 more 2025-03-05 6.2 Medium
Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access to the module via FTP.
CVE-2023-2062 1 Mitsubishielectric 8 Fx5-enet\/ip, Fx5-enet\/ip Firmware, Rj71eip91 and 5 more 2025-03-05 6.2 Medium
Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP. This vulnerability results in authentication bypass vulnerability, which allows the attacker to access MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP via FTP.
CVE-2023-2063 1 Mitsubishielectric 8 Fx5-enet\/ip, Fx5-enet\/ip Firmware, Rj71eip91 and 5 more 2025-03-05 6.3 Medium
Unrestricted Upload of File with Dangerous Type vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to cause information disclosure, tampering, deletion or destruction via file upload/download. As a result, the attacker may be able to exploit this for further attacks.
CVE-2023-2846 1 Mitsubishielectric 300 Fx3g-14mr\/ds, Fx3g-14mr\/ds Firmware, Fx3g-14mr\/es and 297 more 2025-03-05 7.5 High
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series main modules allows a remote unauthenticated attacker to cancel the password/keyword setting and login to the affected products by sending specially crafted packets.
CVE-2023-3373 1 Mitsubishielectric 4 Gs21, Gs21 Firmware, Gt21 and 1 more 2025-02-27 5.9 Medium
Predictable Exact Value from Previous Values vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT21 model versions 01.49.000 and prior and GOT SIMPLE Series GS21 model versions 01.49.000 and prior allows a remote unauthenticated attacker to hijack data connections (session hijacking) or prevent legitimate users from establishing data connections (to cause DoS condition) by guessing the listening port of the data connection on FTP server and connecting to it.
CVE-2023-4562 1 Mitsubishielectric 380 Fx3g-14 Mr\/ds, Fx3g-14 Mr\/ds Firmware, Fx3g-14 Mr\/es and 377 more 2025-02-27 9.1 Critical
Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegitimate messages.
CVE-2023-4625 1 Mitsubishielectric 126 Fx5s-30mr\/es, Fx5s-30mr\/es Firmware, Fx5s-30mt\/es and 123 more 2025-02-27 5.3 Medium
Improper Restriction of Excessive Authentication Attempts vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F/iQ-R Series CPU modules Web server function allows a remote unauthenticated attacker to prevent legitimate users from logging into the Web server function for a certain period after the attacker has attempted to log in illegally by continuously attempting unauthorized login to the Web server function. The impact of this vulnerability will persist while the attacker continues to attempt unauthorized login.
CVE-2023-4699 1 Mitsubishielectric 432 Fx3g-14mr\/ds, Fx3g-14mr\/ds Firmware, Fx3g-14mr\/es and 429 more 2025-02-26 10 Critical
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC-F Series CPU modules, MELSEC iQ-F Series, MELSEC iQ-R series CPU modules, MELSEC iQ-R series, MELSEC iQ-L series, MELSEC Q series, MELSEC-L series, Mitsubishi Electric CNC M800V/M80V series, Mitsubishi Electric CNC M800/M80/E80 series and Mitsubishi Electric CNC M700V/M70V/E70 series allows a remote unauthenticated attacker to execute arbitrary commands by sending specific packets to the affected products. This could lead to disclose or tamper with information by reading or writing control programs, or cause a denial-of-service (DoS) condition on the products by resetting the memory contents of the products to factory settings or resetting the products remotely.
CVE-2023-6943 1 Mitsubishielectric 10 Ezsocket, Fr Configurator2, Got1000 and 7 more 2025-02-13 9.8 Critical
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
CVE-2023-6942 1 Mitsubishielectric 10 Ezsocket, Fr Configurator2, Got1000 and 7 more 2025-02-13 7.5 High
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.
CVE-2023-1618 1 Mitsubishielectric 2 Melsec Ws0-geth00200, Melsec Ws0-geth00200 Firmware 2025-02-12 7.5 High
Active Debug Code vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 Serial number 2310 **** and prior allows a remote unauthenticated attacker to bypass authentication and illegally log into the affected module by connecting to it via telnet which is hidden function and is enabled by default when shipped from the factory. As a result, a remote attacker with unauthorized login can reset the module, and if certain conditions are met, he/she can disclose or tamper with the module's configuration or rewrite the firmware.
CVE-2023-1285 1 Mitsubishielectric 2 Gc-enet-com, Gc-enet-com Firmware 2025-02-06 7.5 High
Signal Handler Race Condition vulnerability in Mitsubishi Electric India GC-ENET-COM whose first 2 digits of 11-digit serial number of unit are "16" allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in Ethernet communication by sending a large number of specially crafted packets to any UDP port when GC-ENET-COM is configured as a Modbus TCP Server. The communication resumes only when the power of the main unit is turned off and on or when the GC-ENET-COM is hot-swapped from the main unit.
CVE-2024-9852 2 Iconics, Mitsubishielectric 3 Genesis64, Genesis64, Mc Works64 2024-12-06 7.8 High
Uncontrolled Search Path Element vulnerability in ICONICS GENESIS64 all versions, Mitsubishi Electric GENESIS64 all versions and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.
CVE-2024-8300 2 Iconics, Mitsubishielectric 2 Genesis64, Genesis64 2024-12-06 7 High
Dead Code vulnerability in ICONICS GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 and Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.
CVE-2024-8299 2 Iconics, Mitsubishielectric 2 Genesis64, Mc Works64 2024-12-06 7.8 High
Uncontrolled Search Path Element vulnerability in ICONICS GENESIS64 all versions, Mitsubishi Electric GENESIS64 all versions and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.
CVE-2023-3346 1 Mitsubishielectric 42 C80, C80 Firmware, E70 and 39 more 2024-12-04 9.8 Critical
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in MITSUBSHI CNC Series allows a remote unauthenticated attacker to cause Denial of Service (DoS) condition and execute arbitrary code on the product by sending specially crafted packets. In addition, system reset is required for recovery.
CVE-2023-5247 1 Mitsubishielectric 4 Gx Works3, Melsoft Iq Appportal, Melsoft Navigator and 1 more 2024-12-02 7.8 High
Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition.