Filtered by vendor Ni Subscriptions
Total 34 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2024-10495 1 Ni 1 Labview 2025-03-04 7.8 High
An out of bounds read due to improper input validation when loading the font table in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions.
CVE-2024-10494 1 Ni 1 Labview 2025-03-04 7.8 High
An out of bounds read due to improper input validation in HeapObjMapImpl.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions.
CVE-2024-10496 1 Ni 1 Labview 2025-03-04 7.8 High
An out of bounds read due to improper input validation in BuildFontMap in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions.
CVE-2024-23610 1 Ni 1 Labview 2025-02-27 7.8 High
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
CVE-2024-23611 1 Ni 1 Labview 2025-02-27 7.8 High
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
CVE-2024-6806 1 Ni 1 Veristand 2024-11-21 9.8 Critical
The NI VeriStand Gateway is missing authorization checks when an actor attempts to access Project resources. These missing checks may result in remote code execution. This affects NI VeriStand 2024 Q2 and prior versions.
CVE-2024-6805 1 Ni 1 Veristand 2024-11-21 7.5 High
The NI VeriStand Gateway is missing authorization checks when an actor attempts to access File Transfer resources. These missing checks may result in information disclosure or remote code execution. This affects NI VeriStand 2024 Q2 and prior versions.
CVE-2024-6794 1 Ni 1 Veristand 2024-11-21 9.8 Critical
A deserialization of untrusted data vulnerability exists in NI VeriStand Waveform Streaming Server that may result in remote code execution. Successful exploitation requires an attacker to send a specially crafted message. These vulnerabilities affect NI VeriStand 2024 Q2 and prior versions.
CVE-2024-6793 1 Ni 1 Veristand 2024-11-21 9.8 Critical
A deserialization of untrusted data vulnerability exists in NI VeriStand DataLogging Server that may result in remote code execution. Successful exploitation requires an attacker to send a specially crafted message. These vulnerabilities affect NI VeriStand 2024 Q2 and prior versions.
CVE-2024-6791 1 Ni 1 Veristand 2024-11-21 7.8 High
A directory path traversal vulnerability exists when loading a vsmodel file in NI VeriStand that may result in remote code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .vsmodel file. This vulnerability affects VeriStand 2024 Q2 and prior versions.
CVE-2024-6122 1 Ni 2 Flexlogger, Systemlink 2024-11-21 5.5 Medium
An incorrect permission in the installation directory for the shared NI SystemLink Server KeyValueDatabase service may result in information disclosure via local access. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service.
CVE-2024-6121 1 Ni 2 Flexlogger, Systemlink 2024-11-21 7.8 High
An out-of-date version of Redis shipped with NI SystemLink Server is susceptible to multiple vulnerabilities, including CVE-2022-24834. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service.
CVE-2024-4081 1 Ni 1 Labview 2024-11-21 7.8 High
A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions.
CVE-2024-4080 1 Ni 1 Labview 2024-11-21 7.8 High
A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
CVE-2024-4079 1 Ni 1 Labview 2024-11-21 7.8 High
An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
CVE-2024-23612 1 Ni 1 Labview 2024-11-21 7.8 High
An improper error handling vulnerability in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
CVE-2024-23609 1 Ni 1 Labview 2024-11-21 7.8 High
An improper error handling vulnerability in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
CVE-2023-5136 1 Ni 4 Diadem, Flexlogger, Topografix Data Plugin and 1 more 2024-11-21 5.5 Medium
An incorrect permission assignment in the TopoGrafix DataPlugin for GPX could result in information disclosure. An attacker could exploit this vulnerability by getting a user to open a specially crafted data file.
CVE-2023-4601 2 Microsoft, Ni 2 Windows, System Configuration 2024-11-21 8.1 High
A stack-based buffer overflow vulnerability exists in NI System Configuration that could result in information disclosure and/or arbitrary code execution. Successful exploitation requires that an attacker can provide a specially crafted response. This affects NI System Configuration 2023 Q3 and all previous versions.
CVE-2023-4570 1 Ni 1 Measurementlink 2024-11-21 8.8 High
An improper access restriction in NI MeasurementLink Python services could allow an attacker on an adjacent network to reach services exposed on localhost. These services were previously thought to be unreachable outside of the node. This affects measurement plug-ins written in Python using version 1.1.0 of the ni-measurementlink-service Python package and all previous versions.